Figure 30.
The Device Module Manager Window: RS-232 Tab
•
Sync Scaler to Matrix Switcher — Select this to open a secondary
window. Within that window enter the IP address of the matrix switcher that is
connected to the Annotator. If required enter the password, then click Connect to
Matrix. Select the output number from the Matrix Output to Annotator
drop-down list and click Take. The Matrix Status section displays the matrix output
that is being monitored and the tied input. The Matrix Size section displays the current
Matrix size (for example a 16 x 16 I/O unit) being used.
Figure 31.
Sync to Matrix Switcher Window
NOTE: The matrix switcher must be connected to via a configured input on the
Annotator. See page 26 for information.
The matrix and the Annotator must to be connected to an active
network at all times to allow the products to remain synchronized. If the
connection is lost, the script needs to be restarted by either sending the
SIS command (E
1AE
}) or by power cycling the Annotator.
Click Refresh Status to update the status of the matrix switcher. Refreshing the
status returns updated information about which Annotator input is tied to a particular
matrix output.
If the matrix IP address needs to be changed or which output of the matrix the
Annotator is connected to, click Remove Sync Scripts
.
Annotator • SPPCP