Resetting the Unit with the Reset Button

There are four reset modes (numbered 1, 3, 4, and 5 for the sake of comparison with
Extron IPL products) that you can access by pressing the Reset button on the rear panel.
The Reset button is recessed, so use a pointed stylus, ballpoint pen, or Extron Tweeker to
press it.

See the table

on page 13 for a summary of the reset modes.

CAUTION: Review the reset modes carefully. Using the wrong reset mode may result

in unintended loss of flash memory programming, port reassignment, or
processor reboot.

NOTE: The reset modes listed in the table close all open IP and Telnet connections and

close all sockets. Also, each mode is a separate function, not a continuation
from mode 1 to mode 5.

RESE

T

RESET

RESET

RESE

T

Release, then

immediately

press and release again. Reset
LED flashes in confirmation.

Modes 3, 4, and 5

Press and

hold

the Reset button.

Mode 1

Reset LED flashes

once,

twice, or three times.

Press and

hold for

3, 6, or 9 seconds.

Apply Power

1

2

RESE

T

Release Reset button.

Figure 5.

Resetting the Annotator

NOTE: After a mode 1 reset is performed, update the Annotators’s firmware to the

latest version. Do not operate the firmware version that results from the
mode 1 reset. If the factory default firmware is to be used, that version must
be uploaded again.

If you do not want to update firmware, or you performed a mode 1 reset by
mistake, cycle power to the device to return to the firmware version that was
running before the mode 1 reset. Use the 0Q SIS command to confirm that
the factory default firmware is no longer running (look for the asterisk [*]
following the version number).

See the table

on next page for a summary of the reset modes.

12

Annotator • Rear Panel Features and Connections