Extron Electronics Annotator User Guide User Manual
Page 65
Command
ASCII (T
elnet)
(host to pr
ocessor)
URL Encoded (W
eb)
(host to pr
ocessor)
Response
(pr
ocessor to host)
Additional description
Configur
e r
edir
ect mode
EX12%
*
X14#
*
X14$
*
X13!
CD
}
W
X12%
%2A
X14#
%2A
X14$
%2A
X13!
CD
|
C
pn
X12%•
C
cd
X14#
,X14$
,X13!]
Terminate r
edir
ect mode
EX12%
*0CD
}
W
X12%
%2A0CD
|
Cpn
X12%•
Ccd00000,00000,
00000L
]
Read r
edir
ect mode
EX12%
CD
}
W
X12%
CD
|
X14#
,X14$
,X13!]
Ether
net data port
Set curr
ent conn port time-out
E
0
*
X14@
TC
}
W0%2A
X14@
TC
|
Pti0*
X14@]
Read curr
ent conn port time-
out
E
0
TC
}
W0TC
|
X14@]
Set global IP port time-out
E
1
*
X14@
TC
}
W1%2A
X14@
TC
|
Pti1*
X14@]
Read global IP port time-out
E
1TC
}
W1TC
|
X14@]
Dir
ectories
Change/cr
eate dir
ectory
E
path/director
y/
CJ
}
Wpath/directory/%2FCJ
|
Dir
•
path/directory/
]
Back to r
oot dir
ectory
E
/
CJ
}
W%2
F
CJ
|
Dir
•
/
]
Up one dir
ectory
E
~
CJ
}
W%
2E
%2
E
CJ
|
Dir
•
path/directory/
]
V
iew curr
ent dir
ectory
E
CJ
}
WCJ
|
path/directory/
]
director
y
= A text string drawn fr
om the alphabet (A-Z), digits (0-9), minus sign/hyphen (-). No
blank or space characters ar
e permitted as part of the name.
No distinction is made between upper and lower case. The first character must be an alpha charact
er
.
NOTE:
A dir
ectory does not truly exist until a file has been copied into th
at path.
Unlike various PC operating systems, a file and dir
ectory on the Extr
on pr
oduct ar
e allowed to have the same name.
The curr
ent dir
ectory is a per
-connection setting. It begins at the r
oot for each IP session.
NOTE:
X
12%
= specific serial port number (01-03), 01 = COM1 (r
ear panel, bottom port), 02 = COM2 (fr
ont panel config port), 03 = COM3 (r
ear panel, top
port)
X13!
= Parameter (#L or #D) to set either the
Length of message to r
eceive or the
D
elimiter value. # = byte count (for L) or # = a single ASCII ch
aracter
expr
essed in decimal form (for D). The parameter is case sensitive.
Byte count is 0 to 32767 (default = 0.)
X14@
= IP connection time-out period specified in 10
-second steps , 1 - 65000 (default = 30
= 300 seconds). If no data is r
eceived in the specified period,
the connection closes.
X14#
= Redir
ection status:
0 = no r
edir
ection, 1 - 3 = r
edir
ect serial communication to COM1, COM2,or COM3
X14$
= T
ime-out period in tens of milliseconds for serial data pass-thr
ough mode, range = 1 - 32767 (default = 10 = 100 ms)
Annotator • SIS Communication and Control
59