beautypg.com

Extron Electronics Annotator User Guide User Manual

Page 48

background image

X2%

= User presets — 1 to 16

X2^

= Input presets — 1 to 128

X2*

= On-screen menu time-out — 1 to 64, in 1 second increments,

0 = always displayed (default = 10)

X3&

= RGB delay — 0 to 50, in 0.1 second increments (default is 05 = 0.5 seconds)

X4)

= Video mute — 01 = mute to black, 02 = mute to white,

00 = unmute (restore image)

X5)

= Annotation type:

0 = eraser

7 = rectangle

1 = pointer

8 = text tool

2 = freehand

9 = spotlight

3 = highlighter

10 = zoom tool

4 = vector line

11 = pan tool

5 = arrow line (arrow appears at the endpoint of the vector)

6 = ellipse

X5!

= Font selection — 16 character file name including *.FNT extension,

0 = default font (Arial)

X5@

= Font size — 8 to 63 point font (default = 8 pt)

X5#

= Line color — 6 bit RGB, 64 total colors

000000 = Black

01

10

11

Red

Value

Green

Value

Blue

Value

Format:

010000 = Dark red (33%)

100000 = Medium red (66%)

110000 = Bright red (100%)

001100 = Bright green (66%)

000011 = Bright blue (default)

111111 = White

010101 = Dark gray (33%)

X5$

= Line weight, eraser, or highlighter width — 1 to 63 pixels wide (default = 8)

X5%

= Aspect ratio

1 = Follow, 2 = Fill

X5^

= On-screen clock:

0 = disabled (default)

1 = date and time

2 = time only

3 = date only

X5&

= Annotation coordinates — 8 digit number with first four being the X coordinate,

the last four the Y coordinate, limits = 1000,1000. Fixed for any output rate.
Example, (0,0) = 00000000 = top left; (500,500) = 05000500 = screen center.

X7%

= Scan converter output format

0 = S-video/composite video

1 = YUVi

2 = RGsB

X7^

= Scan converter output standard

0 = NTSC

1 = PAL

X7&

= Scan converter filter level (encoder, horizontal, flicker) — 0 to 3

Annotator • SIS Communication and Control

42