X13& = Data bits: 7, 8 (default = 8)
X13* = Stop bits: 1, 2 (default = 1)
X13( = Serial port type: 0 = RS-232, 1 = RS-422
X14) = Flow control (only the first letter is needed): H = hardware, S = software, N = none
X14! = Data pacing (time between bytes) in miliseconds, 0000 - 1000 (default = 0000 = 0 ms).
X14@ = IP connection time-out period 1 - 65000, in 10-second steps
(default = 30 = 300 seconds). If no data is received during the specified period, the
Ethernet connection closes. Responses are returned with leading zeros.
X14# = Redirection status: 0 = no redirection, 1 - 3 = redirect serial communication from the
specified port (1 = COM1, 2 = COM2, or 3 = COM3) to allow a serial pass-through
mode.
NOTE:
COM1 is rear panel bottom port, COM2 is front panel config port, COM3 is
rear panel top port
.
X14$ = Time-out period in tens of milliseconds for serial data pass-through mode, after
which event data can be inserted into the transmit buffer and the serial port is
released to another source, range = 1 - 32767 (default = 10 = 100 ms).