Extron Electronics Annotator User Guide User Manual
Page 59
![background image](/manuals/311637/59/background.png)
Command
ASCII command
(host to processor)
Response
(processor to host)
Additional description
On-Screen Menu Configuration
Menu time-out
Set menu time-out period
EX2*
MDUR
}
Mdur
X2*]
Sets the menu duration to
X2*
seconds.
View time-out
E
MDUR
}
Mdur
X2*]
View setting.
NOTE:
Setting the time-out to zero disables the On-screen display (OSD) time-out.
Menu display
Set output to show menu
E X@
MSHW
}
Mshw
X@]
Sets which video outputs display the
OSD.
View setting
E
MSHW
}
X@]
View setting.
NOTE:
If the menu is being displayed on one output, annotating in the menu area on outputs not showing the
menu still affects the menu. The area is safe for annotation on any screen after the menu times out and
docks away.
OSD capture button mode
Save to internal memory
E
0MCAP
}
Mcap0
]
Sets the OSD image capture button
to capture the image and save it to
internal flash memory.
Save to external location
E
1MCAP
}
Mcap1
]
Sets the OSD image capture button
to send the image to internal RAM
memory. This mode allows images
to be streamed to an external PC for
archiving/printing.
View setting
E
MCAP
}
1
]
(or 0
]
)
View setting.
Image capture/recall
Image capture/recall to Annotator flash memory
Save image
E
0*filenameMF
}
Ims*filename
]
Saves currently displayed image to
memory under designated name.
Recall image
E
0*filenameRF
}
Imr*filename
]
Recalls displayed image.
Mute image
E
0*0RF
}
Imr0
]
Mutes image on the output and
reveals live input video
Current image
E
RF
}
filename
]
View currently displayed image
name.
NOTE:
The filename must be 16 characters or fewer, including the *.bmp extension.
Image quick capture
Save image to RAM
E
QCAP
}
Qcap
]
Saves currently displayed image to
Annotator RAM.
NOTE:
Qcap response invokes Quick Capture software running on a PC to request image data.
NOTE:
X@ = Output selection: 0 = all outputs (default), 1 = program only (BNC, MTP, optional output card),
2 = preview only (VGA), 3 = none
X2* = On-screen menu time-out — 1 to 64, in 1 second increments, 0 = always displayed (default = 10))
Annotator • SIS Communication and Control