beautypg.com

Extron Electronics Annotator User Guide User Manual

Page 34

background image

Input 1

Input 6

Input 5

Input 4

Input 3

Input 2

Input 64

Output 1 Input 3

Output 6 Input 3

Output 5

Output 4

Output 3

Output 2 Input 3

Annotator #1

Annotator #6

(optional)

Annotator #2

(optional)

Output to display

Output to display

Output to display

Output 4

Output 3

Matrix

Switcher

Figure 17.

Multiple Annotators Connected to a Matrix Switcher

3.

On the Annotator, configure the input as follows:

a.

Switch to input 3 on the Annotator.

b.

Set the following input sampling settings as needed: signal type, horizontal and
vertical start, pixel phase, total pixels, active pixels, and active lines.

NOTE: Do not use the auto detect setting for the input type when using

input presets.

c.

Set the following picture controls as needed: size, position, color, tint, brightness,
contrast, and detail.

d.

Save the adjusted settings as input preset 1.

See the “SIS Communication and

Control” section

, for the SIS commands to save the preset.

NOTE: Each input preset must be saved with the same number as the input

on the matrix switcher. For example, input 24 on the matrix will be
associated with the input preset 24 on the Annotator.

e.

Repeat steps 2 and 3 for each matrix input that is used on the Annotator.

4.

Synchronize the Annotator to the matrix switcher as follows:

a.

Open the control program (SPPCP) and connect to the Annotator.

NOTE: Connection must be via IP (not RS-232).

b.

From the

Tools

menu, select

Sync to Matrix Switcher...

. The Sync to

Matrix Switcher window opens.

c.

In the

IP Address

field, enter the IP address for the matrix switcher.

Annotator • Operation

28