beautypg.com

Extron Electronics Annotator User Guide User Manual

Page 64

background image

Command

ASCII (T

elnet)

(host to pr

ocessor)

URL Encoded (W

eb)

(host to pr

ocessor)

Response

(pr

ocessor to host)

Additional description

Set verbose mode

EX12#

CV

}

W

X12#

CV

|

Vrb

X12#]

Read verbose mode

E

CV

}

WCV

|

X12#]

Event contr

ol

Start events

E

1AE

}

W1AE

|

Ego

]

Stop events

E

0AE

}

W0AE

|

Est

]

Read number of events running

E

AE

}

WAE

|

#####

]

Retur

ns a five-digit

number

.

(tagged r

esponse in verbose mode 2/3)

Emm

#####

]

Verbose mode

Bidir

ectional serial data port

Set parameters

EX12%

*

X13%

,X13^

,

X13&

,X13*

CP

}

W

X12%

%2A

X13%

%2C

X13^

%2C

X13&

%2C

X13*

CP

|

Cpn

X12%•

Ccp

X13%

,X13^

,

X13&

,X13*]

Read parameters

EX12%

CP

}

W

X12%

CP

|

X13%

,X13^

,X13&

,X13*]

Set mode

EX12%

*

X13(

CY

}

W

X12%

%2A

X13(

CY

|

Cpn

X12%•

Cty

X13(]

Read mode

EX12%

CY

}

W

X12%

CY

|

X13(]

Configur

e flow contr

ol

EX12%

*

X14)

,X14!

CF

}

W

X12%

%2A

X14)

%2C

X14!

CF

|

Cpn

X12%•

Cfl

X14)

,X14!]

Read flow contr

ol

EX12%

CF

}

W

X12%

CF

|

X14)

,X14!]

Configur

e r

eceive time-out

EX12%

*

X12&

*

X13)

*

X13#

*

X13!

CE

}

W

X12%

%2A

X12&

%2A

X13)

%2A

X13#

%2A

X13!

CE

|

Cpn

X12%•

Cce

X12&

,X13)

,X13#

,

X13!]

Read r

eceive time-out

EX12%

CE

}

W

X12%

CE

|

X12&

,X13)

,X13#

,X13!]

NOTE:

X12#

= V

erbose mode:

0 = clear/none,1= verbose mode, 2 = tagged, 3 = verbose and t

agged

X12$

= RAM status, 0 = dirty (needs saving), 1 = saved

X12%

= Specific serial port number (01-03), 01 = COM1 (r

ear panel, bottom port), 02 = COM2 (fr

ont panel config port), 03 = COM3 (r

ear panel, top port)

X12&

= T

ime in tens of milliseconds to wait

until

the

first

response

character is r

eceived via a serial port befor

e terminating the curr

ent r

eceive operation.

(Default = 10 = 100 ms, max. = 32767.)

X13)

= T

ime in tens of milliseconds to wait

between characters

being r

eceived via a serial port befor

e terminating the curr

ent command or r

eceive

operation. (Default = 2 = 20 ms, max. = 32767.)

X13!

= Parameter (#L or #D) to set either the

Length of message to r

eceive or the

D

elimiter value. # = byte count (for L) or # = a single ASCII ch

aracter

expr

essed in decimal form (for D). The parameter is case sensitive.

Byte count is 0 to 32767 (default = 0).

X13#

= Priority status for r

eceiving time-outs:

0 = use send data string command parameters (default), 1 = us

e configur

e r

eceive time-out

command parameters

X13%

=

Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600

(default), 14400, 19200, 28800, 38400, 57600, or 115200

X13^

= Parity (only the first letter is needed), O = odd, E = even, N =

none (default), M = mark, S = space

X13&

= Data bits: 7, 8 (default = 8)

X13*

= Stop bits: 1, 2 (default = 1)

X13(

= Serial port type, 0 = RS-232, 1 = RS-422

X14)

= Flow contr

ol (only the first letter is needed), H = har

dwar

e, S = softwar

e, N = none

X14!

= Data pacing (time between bytes) in milliseconds (0000 - 100

0). (default = 0000 = 0 ms).

Annotator • SIS Communication and Control

58