Extron Electronics Annotator User Guide User Manual
Page 64
Command
ASCII (T
elnet)
(host to pr
ocessor)
URL Encoded (W
eb)
(host to pr
ocessor)
Response
(pr
ocessor to host)
Additional description
Set verbose mode
EX12#
CV
}
W
X12#
CV
|
Vrb
X12#]
Read verbose mode
E
CV
}
WCV
|
X12#]
Event contr
ol
Start events
E
1AE
}
W1AE
|
Ego
]
Stop events
E
0AE
}
W0AE
|
Est
]
Read number of events running
E
AE
}
WAE
|
#####
]
Retur
ns a five-digit
number
.
(tagged r
esponse in verbose mode 2/3)
Emm
#####
]
Verbose mode
Bidir
ectional serial data port
Set parameters
EX12%
*
X13%
,X13^
,
X13&
,X13*
CP
}
W
X12%
%2A
X13%
%2C
X13^
%2C
X13&
%2C
X13*
CP
|
Cpn
X12%•
Ccp
X13%
,X13^
,
X13&
,X13*]
Read parameters
EX12%
CP
}
W
X12%
CP
|
X13%
,X13^
,X13&
,X13*]
Set mode
EX12%
*
X13(
CY
}
W
X12%
%2A
X13(
CY
|
Cpn
X12%•
Cty
X13(]
Read mode
EX12%
CY
}
W
X12%
CY
|
X13(]
Configur
e flow contr
ol
EX12%
*
X14)
,X14!
CF
}
W
X12%
%2A
X14)
%2C
X14!
CF
|
Cpn
X12%•
Cfl
X14)
,X14!]
Read flow contr
ol
EX12%
CF
}
W
X12%
CF
|
X14)
,X14!]
Configur
e r
eceive time-out
EX12%
*
X12&
*
X13)
*
X13#
*
X13!
CE
}
W
X12%
%2A
X12&
%2A
X13)
%2A
X13#
%2A
X13!
CE
|
Cpn
X12%•
Cce
X12&
,X13)
,X13#
,
X13!]
Read r
eceive time-out
EX12%
CE
}
W
X12%
CE
|
X12&
,X13)
,X13#
,X13!]
NOTE:
X12#
= V
erbose mode:
0 = clear/none,1= verbose mode, 2 = tagged, 3 = verbose and t
agged
X12$
= RAM status, 0 = dirty (needs saving), 1 = saved
X12%
= Specific serial port number (01-03), 01 = COM1 (r
ear panel, bottom port), 02 = COM2 (fr
ont panel config port), 03 = COM3 (r
ear panel, top port)
X12&
= T
ime in tens of milliseconds to wait
until
the
first
response
character is r
eceived via a serial port befor
e terminating the curr
ent r
eceive operation.
(Default = 10 = 100 ms, max. = 32767.)
X13)
= T
ime in tens of milliseconds to wait
between characters
being r
eceived via a serial port befor
e terminating the curr
ent command or r
eceive
operation. (Default = 2 = 20 ms, max. = 32767.)
X13!
= Parameter (#L or #D) to set either the
Length of message to r
eceive or the
D
elimiter value. # = byte count (for L) or # = a single ASCII ch
aracter
expr
essed in decimal form (for D). The parameter is case sensitive.
Byte count is 0 to 32767 (default = 0).
X13#
= Priority status for r
eceiving time-outs:
0 = use send data string command parameters (default), 1 = us
e configur
e r
eceive time-out
command parameters
X13%
=
Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600
(default), 14400, 19200, 28800, 38400, 57600, or 115200
X13^
= Parity (only the first letter is needed), O = odd, E = even, N =
none (default), M = mark, S = space
X13&
= Data bits: 7, 8 (default = 8)
X13*
= Stop bits: 1, 2 (default = 1)
X13(
= Serial port type, 0 = RS-232, 1 = RS-422
X14)
= Flow contr
ol (only the first letter is needed), H = har
dwar
e, S = softwar
e, N = none
X14!
= Data pacing (time between bytes) in milliseconds (0000 - 100
0). (default = 0000 = 0 ms).
Annotator • SIS Communication and Control
58