DN-11 Process Data Config Write

Select the process write data for I/O Assembly Instances 101/151.

Elements [2] and [3] of this array can be selected. Elements [0]

and [1] of the array are fixed.

Option:

Function:

[110]

Accel Time 2

[111]

Decel Time 2

[190]

Digital & Relay Bus Control

[193]

Pulse Out #27 Bus Control

[195]

Pulse Out #29 Bus Control

[197]

Pulse Out #X30/6 Bus Control

[222]

Jog Accel/Decel Time

[223]

Quick Stop Decel Time

[653]

Terminal 42 Output Bus

Control

[663]

Terminal X30/8 Bus Control

[748]

PCD Feed Forward

[890]

Bus Jog 1 Speed

[891]

Bus Jog 2 Speed

[1280]

Fieldbus CTW 1

[1282]

Fieldbus REF 1

Select the process write data for I/O Assembly Instances
101/151. Elements [2] and [3] of this array can be selected.
Elements [0] and [1] of the array are fixed.

DN-12 Process Data Config Read

Select the process read data for I/O Assembly Instances 101/151.

Elements [2] and [3] of this array can be selected. Elements [0]

and [1] of the array are fixed.

Option:

Function:

[0]

*

None

[515]

Readout: actual setup

[1200]

Control Word

[1201]

Reference [Unit]

[1202]

Reference %

[1203]

Status Word

[1205]

Main Actual Value [%]

[1209]

Custom Readout

[1210]

Power [kW]

[1211]

Power [hp]

[1212]

Motor Voltage

[1213]

Frequency

[1214]

Motor current

[1215]

Frequency [%]

[1216]

Torque [Nm]

[1217]

Speed [RPM]

[1218]

Motor Thermal

[1219]

KTY sensor temperature

[1220]

Motor Angle

[1221]

Torque [%] High Res.

[1222]

Torque [%]

[1225]

Torque [Nm] High

[1230]

DC Link Voltage

[1232]

Brake Energy /s

DN-12 Process Data Config Read

Select the process read data for I/O Assembly Instances 101/151.

Elements [2] and [3] of this array can be selected. Elements [0]

and [1] of the array are fixed.

Option:

Function:

[1233]

Brake Energy /2 min

[1234]

Heatsink Temp.

[1235]

Drive Thermal

[1238]

Logic Controller State

[1239]

Control Card Temp.

[1248]

Speed Ref. After Ramp [RPM]

[1250]

External Reference

[1251]

Pulse Reference

[1252]

Feedback[Unit]

[1253]

Digi Pot Reference

[1257]

Feedback [RPM]

[1260]

Digital Input

[1261]

Terminal 53 Switch Setting

[1262]

Analog Input 53

[1263]

Terminal 54 Switch Setting

[1264]

Analog Input 54

[1265]

Analog Output 42 [mA]

[1266]

Digital Output [bin]

[1267]

Freq. Input #29 [Hz]

[1268]

Freq. Input #33 [Hz]

[1269]

Pulse Output #27 [Hz]

[1270]

Pulse Output #29 [Hz]

[1271]

Relay Output [bin]

[1272]

Counter A

[1273]

Counter B

[1274]

Prec. Stop Counter

[1275]

Analog In X30/11

[1276]

Analog In X30/12

[1277]

Analog Out X30/8 [mA]

[1284]

Comm. Option STW

[1285]

Drive Port CTW 1

[1287]

Bus Readout Alarm/Warning

[1290]

Alarm Word

[1291]

Alarm Word 2

[1292]

Warning Word

[1293]

Warning Word 2

[1294]

Ext. Status Word

[1500]

Operating hours

[1501]

Running Hours

[1502]

kWh Counter

Parameter Descriptions

AF-650 GP Programming Guide

94

DET-618C

3

3