GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual
Page 148
Par. No.
#
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion
index
Type
H-48
Clockwise Direction
[0] Normal
All set-ups
FALSE
-
Uint8
H-49
Motor Angle Offset Adjust
[0] Manual
All set-ups
FALSE
-
Uint8
H-5#
H-50
Motor Magnetisation at Zero Speed
100 %
All set-ups
TRUE
0
Uint16
H-51
Min Speed Normal Magnetising [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
H-52
Min Speed Normal Magnetising [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
H-53
Model Shift Frequency
ExpressionLimit
All set-ups
FALSE
-1
Uint16
H-54
Voltage reduction in fieldweakening
0 V
All set-ups
FALSE
0
Uint8
H-55
U/f Characteristic - U
ExpressionLimit
All set-ups
TRUE
-1
Uint16
H-56
U/f Characteristic - F
ExpressionLimit
All set-ups
TRUE
-1
Uint16
H-58
Flystart Test Pulses Current
ExpressionLimit
All set-ups
FALSE
0
Uint16
H-59
Flystart Test Pulses Frequency
ExpressionLimit
All set-ups
FALSE
0
Uint16
H-6#
H-61
High Speed Load Compensation
100 %
All set-ups
TRUE
0
Int16
H-64
Resonance Dampening
100 %
All set-ups
TRUE
0
Uint16
H-65
Resonance Dampening Time Constant
5 ms
All set-ups
TRUE
-3
Uint8
H-66
Min. Current at Low Speed
ExpressionLimit
All set-ups
TRUE
0
Uint32
H-67
Torque Limit Factor Source
[0] No function
All set-ups
TRUE
-
Uint8
H-68
Speed Limit Factor Source
[0] No function
All set-ups
TRUE
-
Uint8
H-7#
H-70
Warning Current Low
0 A
All set-ups
TRUE
-2
Uint32
H-71
Warning Current High
ExpressionLimit
All set-ups
TRUE
-2
Uint32
H-72
Warning Speed Low
0 RPM
All set-ups
TRUE
67
Uint16
H-73
Warning Speed High
ExpressionLimit
All set-ups
TRUE
67
Uint16
H-74
Warning Reference Low
-999999.999 N/A
All set-ups
TRUE
-3
Int32
H-75
Warning Reference High
999999.999 N/A
All set-ups
TRUE
-3
Int32
H-76
Warning Feedback Low
-999999.999 ReferenceFeed-
backUnit
All set-ups
TRUE
-3
Int32
H-77
Warning Feedback High
999999.999 ReferenceFeed-
backUnit
All set-ups
TRUE
-3
Int32
H-78
Missing Motor Phase Function
ExpressionLimit
All set-ups
TRUE
-
Uint8
H-8#
H-80
Function at Stop
[0] Coast
All set-ups
TRUE
-
Uint8
H-81
Min Speed for Function at Stop [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
H-82
Min Speed for Function at Stop [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
H-83
Precise Stop Function
[0] Precise ramp stop
All set-ups
FALSE
-
Uint8
H-84
Precise Stop Counter Value
100000 N/A
All set-ups
TRUE
0
Uint32
H-85
Precise Stop Speed Compensation Delay
10 ms
All set-ups
TRUE
-3
Uint8
H-87
Load Type
[0] Passive load
All set-ups
TRUE
-
Uint8
H-88
Minimum Inertia
ExpressionLimit
All set-ups
FALSE
-4
Uint32
H-89
Maximum Inertia
ExpressionLimit
All set-ups
FALSE
-4
Uint32
H-9#
H-95
KTY Sensor Type
[0] KTY Sensor 1
All set-ups
TRUE
-
Uint8
H-96
KTY Thermistor Input
[0] None
All set-ups
TRUE
-
Uint8
H-97
KTY Threshold level
80 °C
1 set-up
TRUE
100
Int16
Parameter Lists
AF-650 GP Programming Guide
DET-618C
147
4
4