10 o-## options/comms – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual
Page 151
Par. No.
#
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion
index
Type
SP-89
Decel Time 3 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
SP-9#
SP-90
Decel Time 3 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
SP-92
Accel/Decel Ramp 4 Type
[0] Linear
All set-ups
TRUE
-
Uint8
SP-95
Accel Time 4 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
SP-96
Accel Time 4 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
SP-97
Decel Time 4 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
SP-98
Decel Time 4 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
4.1.10 O-## Options/Comms
Par. No.
#
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion
index
Type
O-0#
O-01
Control Site
[0] Digital and ctrl.word
All set-ups
TRUE
-
Uint8
O-02
Control Word Source
ExpressionLimit
All set-ups
TRUE
-
Uint8
O-03
Control Word Timeout Time
1 s
1 set-up
TRUE
-1
Uint32
O-04
Control Word Timeout Function
ExpressionLimit
1 set-up
TRUE
-
Uint8
O-05
End-of-Timeout Function
[1] Resume set-up
1 set-up
TRUE
-
Uint8
O-06
Reset Control Word Timeout
[0] Do not reset
All set-ups
TRUE
-
Uint8
O-07
Diagnosis Trigger
[0] Disable
2 set-ups
TRUE
-
Uint8
O-08
Readout Filtering
ExpressionLimit
All set-ups
TRUE
-
Uint8
O-1#
O-10
Control Word Profile
[0] Drive Profile
All set-ups
TRUE
-
Uint8
O-13
Configurable Status Word STW
ExpressionLimit
All set-ups
TRUE
-
Uint8
O-14
Configurable Control Word CTW
[1] Profile default
All set-ups
TRUE
-
Uint8
O-19
Product Code
ExpressionLimit
1 set-up
TRUE
0
Uint32
O-3#
O-30
Protocol
[2] Modbus RTU
1 set-up
TRUE
-
Uint8
O-31
Address
1 N/A
1 set-up
TRUE
0
Uint8
O-32
Drive Port Baud Rate
ExpressionLimit
1 set-up
TRUE
-
Uint8
O-33
Drive Port Parity
[0] Even Parity, 1 Stop Bit
1 set-up
TRUE
-
Uint8
O-34
Estimated cycle time
0 ms
2 set-ups
TRUE
-3
Uint32
O-35
Minimum Response Delay
10 ms
All set-ups
TRUE
-3
Uint16
O-36
Max Response Delay
ExpressionLimit
1 set-up
TRUE
-3
Uint16
O-37
Max Inter-Char Delay
ExpressionLimit
1 set-up
TRUE
-5
Uint16
O-4#
O-40
Telegram Selection
[1] Standard telegram 1
2 set-ups
TRUE
-
Uint8
O-41
Parameters for Signals
0
All set-ups
FALSE
-
Uint16
O-42
PCD Write Configuration
ExpressionLimit
2 set-ups
TRUE
-
Uint16
O-43
PCD Read Configuration
ExpressionLimit
2 set-ups
TRUE
-
Uint16
O-5#
O-50
Coasting Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
O-51
Quick Stop Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
O-52
DC Brake Select
ExpressionLimit
All set-ups
TRUE
-
Uint8
O-53
Start Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
O-54
Reversing Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
O-55
Set-up Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
O-56
Preset Reference Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
O-57
Profidrive OFF2 Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
Parameter Lists
AF-650 GP Programming Guide
150
DET-618C
4