GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual
Page 48

[11]
At torque limit
The torque limit set in F-40 Torque Limiter
(Driving) or F-41 has been exceeded.
[12]
Out of current
range
The motor current is outside the range
set in F-43 Current Limit.
[13]
Below current,
low
Motor current is lower than set in
[14]
Above current,
high
Motor current is higher than set in
[15]
Out of range
Output frequency is outside the
frequency range set in H-70 Warning
Current Low and H-71 Warning Current
[16]
Below speed,
low
Output speed is lower than the setting in
[17]
Above speed,
high
Output speed is higher than the setting
[18]
Out of feedback
range
Feedback is outside the range set in
[19]
Below feedback
low
Feedback is below the limit set in
[20]
Above feedback
high
Feedback is above the limit set in
[21]
Thermal
warning
The thermal warning turns on when the
temperature exceeds the limit in the
motor, the frequency converter, the
brake resistor, or the thermistor.
[22]
Ready, no
thermal
warning
Frequency converter is ready for
operation and there is no over-
temperature warning.
[23]
Remote, ready,
no thermal
warning
Frequency converter is ready for
operation and is in Auto mode. There is
no over-temperature warning.
[24]
Ready, no
over-/ under
voltage
Frequency converter is ready for
operation and the mains voltage is
within the specified voltage range (see
General Specifications section in the
relevant Design Guide).
[25]
Reverse
Reversing. Logic ‘1’ when CW rotation of
the motor. Logic ‘0’ when CCW rotation
of the motor. If the motor is not rotating
the output will follow the reference.
[26]
Bus OK
Active communication (no time-out) via
the serial communication port.
[27]
Torque limit
and stop
Use in performing a coasting stop and in
torque limit condition. If the frequency
converter has received a stop signal and
is at the torque limit, the signal is Logic
‘0’.
[28]
Brake, no brake
warning
Brake is active and there are no
warnings.
[29]
Brake ready, no
fault
Brake is ready for operation and there
are no faults.
[30]
Brake fault
(IGBT)
Output is Logic ‘1’ when the brake IGBT
is short-circuited. Use this function to
protect the frequency converter if there
is a fault on the brake modules. Use the
output/relay to cut out the main voltage
from the frequency converter.
[31]
Relay 123
Relay is activated when Control Word [0]
is selected in parameter group O-##.
[32]
Mechanical
brake control
Enables control of an external
mechanical brake, see description in
parameter group B-2# Mechanical Brake.
[40]
Out of ref range Active when the actual speed is outside
settings in parameter H-72 to H-75.
[41]
Below reference
low
Active when actual speed is below speed
reference setting.
[42]
Above
reference high
Active when actual speed is above speed
reference setting.
[45]
Bus Ctrl
Controls output via bus. The state of the
output is set in E-90 Digital & Relay Bus
Control. The output state is retained in
the event of bus time-out.
[46]
Bus Ctrl On at
timeout
Controls output via bus. The state of the
output is set in E-90 Digital & Relay Bus
Control. In the event of bus time-out the
output state is set high (On).
[47]
Bus Ctrl Off at
timeout
Controls output via bus. The state of the
output is set in E-90 Digital & Relay Bus
Control. In the event of bus time-out the
output state is set low (Off).
[55]
Pulse output
[60]
Comparator 0
See parameter group LC-1#. If
Comparator 0 is evaluated as TRUE, the
output will go high. Otherwise, it will be
low.
[61]
Comparator 1
See parameter group LC-1#. If
Comparator 1 is evaluated as TRUE, the
output will go high. Otherwise, it will be
low.
[62]
Comparator 2
See parameter group LC-1#. If
Comparator 2 is evaluated as TRUE, the
output will go high. Otherwise, it will be
low.
[63]
Comparator 3
See parameter group LC-1#. If
Comparator 3 is evaluated as TRUE, the
output will go high. Otherwise, it will be
low.
[64]
Comparator 4
See parameter group LC-1#. If
Comparator 4 is evaluated as TRUE, the
output will go high. Otherwise, it will be
low.
[65]
Comparator 5
See parameter group LC-1#. If
Comparator 5 is evaluated as TRUE, the
output will go high. Otherwise, it will be
low.
[70]
Logic Rule 0
See parameter group LC-4#. If Logic Rule
0 is evaluated as TRUE, the output will
go high. Otherwise, it will be low.
[71]
Logic Rule 1
See parameter group LC-4#. If Logic Rule
1 is evaluated as TRUE, the output will
go high. Otherwise, it will be low.
Parameter Descriptions
AF-650 GP Programming Guide
DET-618C
47
3