beautypg.com

EVS XTnano Version 11.02 - July 2013 Operation Manual User Manual

Page 64

background image

In the Remote Panel Interface

To restripe the timecode of a clip, proceed as follows:

1. Recall the clip by pressing the corresponding F_ key.

2. Move the jog dial to reach the picture where you want to define a new timecode.

3. Press the MENU key to access the secondary menu.

4. Press SHIFT+C to call the Set TC function.

5. Enter the new timecode for the current picture.

6. In 59.94 Hz modes (NTSC), press SHIFT+MENU to select between 'Drop Frame'

and 'Non Drop Frame' modes.

7. Press the D key to select 'CAM' or 'CLIP' mode.

In 'CAM' mode, only the timecode of the camera angle loaded on the primary
channel will be changed.

In 'CLIP' mode, the timecode of all camera angles of the clip will be changed.

8. Press ENTER to confirm or MENU to cancel.

The primary timecode of the entire clip is updated according to the new timecode value so
that the timecode remains continuous over the whole clip.

Next time this function is called, the value previously used will be set as default.

In the VGA Interface

To restripe the timecode of a clip, proceed as follows:

1. Move the cursor on the desired clip and press ENTER or click on it with the stylus to

recall it.

2. Press ALT-T on the keyboard to call the SET TC function. The following Set

Timecode screen is displayed:

56

4. Clip Management

EVS Broadcast Equipment S.A.

Issue 11.02.A July 2013