8 vlan commands, Table 86 vlan commands, Section 32.11.8 on – ZyXEL Communications VDSL SWITCH VES-1616F-3X User Manual
Page 240

Chapter 32 Introducing the Commands
VES-1616F-3x Series User’s Guide
240
32.11.8 vlan Commands
The following table lists the
vlan
commands in configuration mode.
us <1|2>
Sets a rate adaptive mode for the
upstream traffic
1: Manual
2: AdaptAtInit
13
rateratio ds
<0..100>
Specify the downstream data rate
allocated for the fast and slow
channels.
0: slow channel
100: fast channel
13
us
<0..100>
Specify the upstream data rate
allocated for the fast and slow
channels.
0: slow channel
100: fast channel
13
snr dsmax
<0..127>
Sets the maximum downstream
SNR (Signal to Noise Ratio).
13
dsmin <0..127>
Sets the minimum downstream
SNR (Signal to Noise Ratio).
13
dstarget
<0..127>
Sets the target downstream SNR
(Signal to Noise Ratio).
13
usmax <0..127>
Sets the maximum upstream
SNR (Signal to Noise Ratio).
13
usmin <0..127>
Sets the minimum upstream SNR
(Signal to Noise Ratio).
13
ustarget
<0..127>
Sets the target upstream SNR
(Signal to Noise Ratio).
13
targetslowburst ds
<0..1275>
Sets the target burst rate for the
downstream slow channel.
13
us <0..1275>
Sets the target burst rate for the
upstream slow channel.
13
Table 85 vdsl-profile Commands (continued)
COMMAND
DESCRIPTION
P
Table 86 vlan Commands
COMMAND
DESCRIPTION
P
vlan <1-4094>
Creates a new VLAN group.
13
exit
Leaves the VLAN configuration mode.
13
fixed list> Specifies the port(s) to be a permanent member of this VLAN group. 13 forbidden Specifies the port(s) you want to prohibit from joining this VLAN group. 13 help Displays a list of available VLAN commands. 13 inactive Disables the specified VLAN. 13 ip address Sets the IP address and subnet mask of the switch in the specified VLAN for packet loopback test. 13