Paradyne 9788 User Manual
Page 90
4. Configuration Options
4-50
December
2002
9700-A2-GB20-20
FTP Login Required
Possible Settings: Enable, Disable
Default Setting: Disable
Specifies if a login ID and password are required for an FTP session. If required, the login
used is the same login used for a menu-driven user interface session. This option does
not affect the TS Access Management Link.
Enable – User is prompted for a login ID and password.
Disable – No login is required for an FTP session.
FTP Max Transfer Rate (Kbps)
Possible Settings:
–
9720: 1 – 144
–
9783: 1 – 2320
–
9788: 1 – 2312
Default Setting:
–
9720: 144
–
9783: 2320
–
9788: 2312
Sets the maximum transmit and receive rate of a file transfer via management PVCs. This
option allows new firmware and configuration files to be downloaded in the background
using selected bandwidth without interfering with normal operation. Files can be
downloaded quickly using the default settings or downloaded at a slower rate over an
extended period of time by selecting a slower speed. Based on TCP flow control, the
system FTP server throttles bandwidth to match this setting.
1 –
maximum – Sets the line speed from 1 Kbps to the maximum management speed.
Table 4-21. Telnet and FTP Session Options (3 of 3)