Paradyne 9788 User Manual
Page 211
8. Troubleshooting
9700-A2-GB20-20
December 2002
8-27
When the ping has completed normally, timed out, or been stopped using the Stop
command, informational fields are displayed as shown in
Table 8-6, Ping
Responses
.
Table 8-6.
Ping Responses
Field
Possible Values
Description
Status
In Progress
Alive
Destination
Unreachable
Ping Timed Out
No route in this
device
Ping has been sent.
Ping was successful.
The host could not be reached. See
RFC 792 for possible causes.
There was no response in the period
specified in Response Timeout.
The IP address is not in the routing
table, and no Default IP Destination is
configured.
Ping Loss Ratio (%)
0–100
The ratio of pings received to pings
transmitted.
Pings Transmitted
1–999999
The number of pings transmitted.
Pings Received
1–999999
The number of pings received.
Pings Lost
1–999999
The number of pings transmitted less the
number of pings received.
Current Roundtrip
Delay
0
1–9999
No measurement exists.
The time in milliseconds that it took to
complete the latest ping.
Minimum Roundtrip
Delay
0
1–9999
No measurement exists.
The least time in milliseconds that it
took to complete a ping during this test.
Maximum Roundtrip
Delay
0
1–9999
No measurement exists.
The most time in milliseconds that it
took to complete a ping during this test.
Average Roundtrip
Delay
0
1–9999
No measurement exists.
The average time in milliseconds that it