Paradyne 9788 User Manual
Page 143
![background image](/manuals/189883/143/background.png)
7. Operation and Maintenance
9700-A2-GB20-20
December 2002
7-7
Table 7-2.
Control Leads
Label
Indication
What It Means
General
OK
Operational
The device’s hardware and firmware are
operational.
Alarm
Alarm Present
The device has detected a fault that may
interfere with operation.
Test
Test in Progress
The unit is in a maintenance mode, such as a
loopback test.
ATM Mode
(9783,
9788)
ATM Mode is Active
The unit is configured for ATM operation. The
front panel ATM LED is on.
Network Interface (9783, 9788)
Data Mode
Data Mode Active
The unit has trained up and is operating in
normal data mode. The front panel DSL LED is
on.
LOS
Loss Of Signal
An LOS condition has been detected on the
network. The front panel ALM LED is on.
Training
Training in Progress
The unit is training and the DSL LED is flashing.
LCD
Loss of Cell Delineation
An LCD alarm condition has been detected. On
the 9783, the front panel ATM LED is yellow.
Network Interface (9720)
OK
DSL Line OK
The unit has trained up and is operating in
normal data mode. The front panel DSL LED is
on.
LMI OK
LMI Operating
The LMI is operating successfully on the first
frame relay link on the network interface.
Port-1 — CSU/DSUs only
OK
Port-1 is Active
The user data port is transmitting and receiving
data.
TXD
Transmit Data
Data is being sent to the far-end device.
RXD
Receive Data
Data is being received from the far-end device.
DTR
Data Terminal Ready
The DTE is not ready to operate.
RTS
Request to Send
The DTE has indicated that it is ready to transmit
data.
Ethernet
OK
Ethernet is Active
The Ethernet connection is transmitting and
receiving data.