8. Troubleshooting

8-24

December

2002

9700-A2-GB20-20

IP Ping Test

An IP Ping can test connectivity between the management data path and the
FrameSaver unit and any FrameSaver unit, router, or NMS to which it has a route.
In addition, the test can be run to access a remote unit for configuration purposes.

Times when you might want to run an IP Ping test are:

To test connectivity between the FrameSaver unit and any FrameSaver unit in
the network to verify that the path is operational. Select

IP Ping Test –

Procedure 1

to ping any far-end FrameSaver unit.

To verify the entire path between a newly installed remote site FrameSaver
unit and the central site NMS. During a remote site installation, an IP Ping test
is typically run from the remote site to ping the NMS at the central site. The
remote FrameSaver unit must have SNMP trap managers configured, and one
of those trap managers must be the central site NMS. Select

IP Ping Test –

Procedure 2

on page 8-29 to ping the NMS at the central site.

To test the path to the NMS trap managers during installation of the central site
FrameSaver unit. The remote FrameSaver unit must have configured the
SNMP trap managers to be sent the Ping. Select

IP Ping Test – Procedure 2

on page 8-29 to ping SNMP trap managers.

Ping Screen Example

main/test/ping 9783-C-SLV

Device Name: Node A 09/11/2002 06:12

IP PING

Target IP Address: 000.000.000.000

Destination Interface: Use Internal Route DLCI: 100 (Net1-ATM 15,255)

Source IP Address: Special 135.90.25.1

Encapsulation: Routed

TOS Byte User Defined 001101

Packet Size: 64

Iteration Count: 1

Inter-ping Delay (sec): 5

Response Timeout (sec): 2

Start

---------------------------------------------------

Status: Alive

Transmit Receive Lost Loss Ratio

Pings: 000000 000000 000000 0000 %

Current Minimum Maximum Average

Roundtrip Delay (ms): 0000 0000 0000 0000

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit