4. Configuration Options

4-36

December

2002

9700-A2-GB20-20

Destination Link

Possible Settings: Net1-FR1
Default Setting: Initially blank

Specifies the frame relay interface used as the destination link; the to end of a from-to
link. The only valid setting for this option is a frame relay interface that has at least one
DLCI or EDLCI defined which is not part of a PVC connection or management link; i.e., if
the network interface has no DLCIs defined, Net1-FR1 does not appear as an option.

Net1-FR1 – Specifies the Network interface as the destination link.

Destination DLCI

Possible Settings: 16 – 1007
Default Setting: Initially blank

Specifies the destination DLCI for a frame relay interface. The DLCI must be defined and
cannot be part of a PVC connection or management link. For multiplexed DLCIs, at least
one EDLCI must be unconnected for the DLCI to be a valid selection.

NOTES:

– Primary Destination DLCI has no value if Primary Destination Link contains no

value.

– For the Diagnostic Feature Set, only one EDLCI per multiplexed DLCI may be used

in the PVC connection.

16 – 1007 – Specifies the DLCI number.

Destination EDLCI

Possible Settings: 0 – 62
Default Setting: Initially blank

Specifies the destination Embedded Data Link Connection Identifier (EDLCI) for a frame
relay interface when a multiplexed DLCI record is selected as one end of a connection.

Display Conditions – This option appears only when the Primary Destination DLCI
contains a multiplexed DLCI and is not applicable when FRF.8 Encapsulation Mode is
set to Translational (see

Table 4-12, Network ATM Options

).

0 – 62 – Specifies the EDLCI number.