beautypg.com

Paradyne 9788 User Manual

Page 148

background image

7. Operation and Maintenance

7-12

December

2002

9700-A2-GB20-20

Resetting Device,
Please Wait ...

Yes was entered for Reset
COM Port usage

field of

the System Paused menu.

No action is needed.

Save Cancelled

Changes were made on the
Easy Install screen, but the
Esc key was pressed or No
was entered in response to
the Save Changes?
prompt.

No action is needed.

Test Active

No higher priority health
and status messages exist,
and a test is running.

Contact service provider if test
initiated by the network.

Wait until the test ends and
message clears.

Cancel all tests from the Test
screen. Path:

Main

Test .

Stop the test from the same
screen the test was started
from.

User Interface Already
in Use

Two Telnet sessions are
active when an attempt to
access the menu-driven
user interface through the
COM port is made.

IP addresses and logins of
the users currently
accessing the interface are
displayed.

Wait and try again.

Contact one of the IP address
users and request that they log
off.

User Interface Idle

Previously active session is
ended, and access via the
COM port is now available.

Log on to the FrameSaver unit.

Session has been ended
due to timeout.

No action is needed.

Value Out of Range

CIR entered for the DLCI is
a number greater than the
maximum allowed.

Enter a valid CIR (0–1536000).

Excess Burst Size entered
for the DLCI is a number
greater than the maximum
allowed.

Enter a valid Excess Burst Size
(0–1536000).

DLCI Number entered is
less than 16 or greater
than 1007.

Enter a valid number (16–1007).

Table 7-3.

Device Messages (5 of 5)

Message

What It Indicates

What To Do

This manual is related to the following products: