4. Configuration Options

9700-A2-GB20-20

December 2002

4-35

Configuring PVC Connections

TS Management is initially enabled and configured on VPI,VCI 0,35 by default.
Any valid DLCI, VPI,VCI can be used.

Main Menu

→Configuration→PVC Connections

From this screen, create the PVC connections and go directly to the Management
PVC screen by selecting the MgmtPVCs function key. See

Configuring

Management PVCs

on page 4-41 for management PVC configuration options.

You can quickly remove unused DLCIs in an existing PVC connection by selecting
the Delete function key and responding Yes to the Remove otherwise unused
components associated with the deleted PVC?

prompt.

Table 4-16. PVC Connections (1 of 2)

Source Link

Possible Settings: Port-1, Net1-FR1
Default Setting: Initially blank

Specifies the frame relay interface that starts a PVC connection; the from end of a from-to
link. The only valid settings for this configuration option are frame relay interfaces that
have at least one DLCI or EDLCI defined that are not part of a PVC connection or
management link. For example, if Port-1 has no DLCIs defined, Port-1 would not appear
as a valid setting.

Port-1 – For the FrameSaver CSU/DSU, specifies the user data port as the source link.

Net1-FR1 – Specifies the Network interface or network data port as the source link.

Clear All – Clears all Link and DLCI settings, and suppresses EDLCIs.

Source DLCI

Possible Settings: 16 – 1007
Default Setting: Initially blank

Specifies the source DLCI for a frame relay interface. The DLCI must be defined and
cannot be part of a PVC connection or management link. For multiplexed DLCIs, at least
one EDLCI must be unconnected for the DLCI to be a valid selection.

NOTE: Source DLCI has no value if Source Link contains no value.

16 – 1007 – Specifies the DLCI number.

Source EDLCI

Possible Settings: 0 – 62
Default Setting: Initially blank

Specifies the source Embedded Data Link Connection Identifier (EDLCI) for a frame relay
interface when a multiplexed DLCI record is selected as one end of a connection.

Display Conditions – This option appears only when Source DLCI contains a
multiplexed DLCI record number, and is not applicable when FRF.8 Encapsulation
Mode is set to Translational (see

Table 4-12, Network ATM Options

).

0 – 62 – Specifies the EDLCI number.