Trap: warmstart, Trap: authenticationfailure – Paradyne 9788 User Manual
Page 247
B. SNMP MIBs, Traps, and RMON Alarm Defaults
9700-A2-GB20-20
December 2002
B-7
Trap: warmStart
This trap indicates that the FrameSaver unit has been reset and has stabilized.
Trap: authenticationFailure
This trap indicates that access to the FrameSaver unit was unsuccessful due to
lack of authentication.
Table B-3.
warmStart Trap
Trap
What It Indicates
Possible Cause
warmStart
FrameSaver unit has just
reinitialized and stabilized
itself.
Reset command sent.
Power disruption.
String:
‘Unit reset.’
Variable-Binding
devLastTrapString
(devHealthAndStatus.mib)
Table B-4.
authenticationFailure Trap
Trap
What It Indicates
Possible Cause
authenticationFailure
Access to the FrameSaver
unit was attempted and failed.
SNMP protocol message not
properly authenticated.
Three unsuccessful attempts
were made via a Telnet session
or locally at the asynchronous
terminal to enter a correct login
user ID/password combination.
IP Address security is enabled
and a message was received
from the SNMP Manager
whose address was not on the
list of approved managers.
String:
‘Unauthorized access attempted.’
(e.g., ‘Unauthorized access
attempted from COM port.’)
Variable-Binding
devLastTrapString
(devHealthAndStatus.mib)