beautypg.com

Paradyne 3161 User Manual

Page 188

background image

C. Configuration Options

C-22

March 2001

3160-A2-GB24-10

ComDisconnect:
Next Edit Clear Prev

Carrier Communication Port Disconnect String. Specifies the communication port’s
disconnect string. The communication port’s disconnect string is sent to the external
device if either you or the DSU/CSU wants to command the external device to disconnect.
The external device must be in command mode before this command can be sent, so the
escape sequence will always be sent before the disconnect string. The disconnect string
is an ASCII text string and may be up to 20 characters in length. If the disconnect string is
NULL, then no disconnect string is sent out.

Edit – Allows you to edit and/or display the disconnect string using the generic text string
entry screen.

Clear – Allows you to clear the disconnect string. The disconnect string is set to a null
string.

NOTES:

– This configuration option is available on carrier-mounted DSU/CSUs only.

– This configuration option is not available if the ComExtDev configuration option is

set to AT or the communication port is disabled.

Com Type: Async
Next Async Sync Prev

Communication Port Type. Specifies whether the communication port uses synchronous
or asynchronous operation when it is configured as the SNMP management link.

Async – Configures the communication port for asynchronous operation.

Sync – Configures the communication port for synchronous operation.

NOTES:

– This configuration option is available on standalone DSU/CSUs only.

– This configuration option is not available if the Com Use configuration option is set

to ASCII, Daisy, or Term. In these cases, the communication port is always
asynchronous.

Com Clk: Int
Next Int Ext Prev

Communication Port Synchronous Clock. Specifies whether the communication port uses
internal or external clocking when it is configured for synchronous operation.

Int – Configures the communication port for internal clocking.

Ext – Configures the communication port for external clocking.

NOTES:

– This configuration option is available on standalone DSU/CSUs only.

– This configuration option is not available if the Com Type configuration option is set

to Async.

Table C-7.

User Interface Configuration Options (5 of 11)

This manual is related to the following products: