Local loopback tests – Paradyne 3161 User Manual
Page 146
8. Testing
8-8
March 2001
3160-A2-GB24-10
Local Loopback Tests
The Local Loopback tests enable you to conduct circuit testing and fault isolation
for the digital line. The supported local loopback tests are:
T
T
T
T
T
T
NOTE:
DLB does not appear when the DTE Drop/Insert (DSX-1) interface is disabled.
The Line Loopback command can be activated and deactivated in response to
commands received over the network interface. The Network Interface
configuration option NET LLB controls whether the DSU/CSU responds to the
commands transmitted on the network interface to initiate LLBs (see
The data port configuration option NET DCLB controls whether the DSU/CSU
responds to inband V.54 commands to initiate DCLB for that port (see
Local loopback tests can be aborted (Abort Command) at any time.
No more than two local loopbacks can be active at any one time. An additional
restriction prohibits certain loopbacks from running at the same time. Valid
loopback combinations listed in
Table 8-2, Valid Loopback Combinations
, are
identified by YES.
Table 8-2.
Valid Loopback Combinations
LLB
PLB
DLB
RLB
DCLB
DTLB
LLB
N/A
NO
YES
YES
NO
YES
PLB
NO
N/A
YES
NO
NO
YES
DLB
YES
YES
N/A
NO
YES
YES
RLB
YES
NO
NO
N/A
NO
YES
DCLB
NO
NO
YES
NO
YES
(on separate ports)
YES
(on separate ports)
DTLB
YES
YES
YES
YES
YES
(on separate ports)
YES
(on separate ports)