Remote terminal adaptors (rtas) – Perle Systems RIO 5500036-17 User Manual
Page 277

RIO Remote I/O System User Guide
Solaris troubleshooting
Page 277
Remote Terminal Adaptors (RTAs)
Problem
Action required
RTA not recognised by system
1. Check physical connections and power.
See
.
2. Run the
rioconfig
utility to update RIO
system settings.
See
RTA not booted by system
1. Check the
rio.cf
file to make sure the RTA
entry exists and contains the
boot
field.
See
page 164
.
2. Delete the
rio.cf
file and run the
rioconfig
utility to recreate the system settings.
See
page 164
and
.
RTA8 LED next to port 5 does not light up
The host card has already assigned 128 ports, if you
haven’t got 128 ports installed, this means that you
have previously removed one or more RTAs from the
network but not deleted them from the configuration.
RTA16 con LED does not light up
You have already installed the maximum number of
RTAs up to 128 ports. This situation may arise if you
have previously removed RTAs from the system but
forgotten to delete them from the configuration using
the rioconfig utility.