Installation (Hardware & Software) — Macintosh Computer G 3-9
If External SCSI Devices Are Connected
Complete these steps if one or more external SCSI devices are connected
to your Macintosh computer; otherwise continue at “Setting the Scanner
SCSI Identification Number” later in this chapter.
CAUTION: Whenever connecting or disconnecting SCSI cables,
be sure power is turned off on all devices in the SCSI chain,
including the computer and the Scanner (turn off the computer
first).
Multiple SCSI devices are connected to the Macintosh computer in a
chain. The following steps will help you determine where you should
place the Scanner in that chain — either at the end of the chain, or in the
middle of the chain.
NOTE: The total cable length connecting all devices must not exceed 15 feet
(4.6 meters).
1. Select your SCSI cable with identical 50-pin SCSI connectors at each
end.
NOTE: This cable is not packed with the Scanner but is available through
Kodak. Refer to “Appendix I — Optional Equipment & Spare Parts List.” This
cable is also widely available from computer retailers; if you obtain a cable
from one of these sources, be certain to obtain a high quality cable with a
continuous EMI shield over the cable and connectors.
50-pin SCSI Connector
50-pin SCSI Connector