1 updating the service processor firmware, 2 example, Updating the service processor firmware – Sun Microsystems Sun Fire X4200 User Manual
Page 97: Example
Chapter 7
Command Line Interface Tasks
7-21
7.14.1
Updating the Service Processor Firmware
Type this command to update the service processor:
load -source
URI
7.14.2
Example
-> load -source tftp://archive/newmainimage
Note –
A firmware upgrade will cause the server and ILOM to be reset. It is
recommended that a clean shutdown of the server be done prior to the upgrade
procedure. An upgrade takes about 20 minutes to complete. ILOM will enter a
special mode to load new firmware. No other tasks can be performed in ILOM until
the firmware upgrade is complete and ILOM is reset.
Are you sure you want to load the specified file (y/n)? y
File upload is complete. Firmware image verification is
complete.
Do you want to update the ILOM OS image (y/n)? n
Do you want to update the host BIOS (y/n)? n
Do you want to preserve the configuration (y/n)?n
Updating firmware in flash RAM:
.
Firmware update is complete.