Sun Microsystems Sun Fire X4200 User Manual
Page 34

2-14
Sun Fire X4100 and Sun Fire X4200 Servers System Management Guide • December 2005
TABLE 2-9
Switch Sensors
Name
Path
Description
bp.locate.btn
/SYS/LOCATE/BTN
Back Panel Locate Button
fp.locate.btn
/SYS/FIOBD/LOCATE/BTN
Front Panel Locate Button
sys.intsw
/SYS/INTSW
Chassis Intrusion Switch
sys.nmi
/SYS/DIAG/BTN
NMI Button
TABLE 2-10
Presence Sensors
Name
Path
Description
fp.prsnt
/SYS/FIOBD/PRSNT
Front IO Board Present
fp.ledbd.prsnt
/SYS/LEDBD/PRSNT
LED Board Present
io.id0.prsnt
/SYS/SASBP/ID0/PRSNT
2 Disk Backplane Present
io.id1.prsnt
/SYS/SASBP/ID1/PRSNT
4 Disk Backplane Present
sys.id
/SYS/ID
System ID
io.f0.prsnt
/SYS/SASBP/FO/PRSNT
I/O Fan Present
TABLE 2-11
System Failure Sensors
Name
Path
Description
sys.fanfail
/SYS/FAN_FAULT/FF_FAIL
Fan Failure
sys.tempfail
/SYS/TEMP_FAULT/FF_FAIL
Over Temperature Failure
sys.psfail
/SYS/PSU_FAULT/FF_FAIL
Power Supply Failure
fp.usbfail
/SYS/FIOBD/FF_USB2
Front USB Over Current Failure
TABLE 2-12
CPU Failure Sensors
Name
Path
Description
p0.fail
/MB/P0/FF_FAIL
CPU0 Failure
p1.fail
/MB/P1/FF_FAIL
CPU1 Failure