2 ilom default settings, 2 how to configure ilom using a serial connection, 1 before you begin – Sun Microsystems Sun Fire X4200 User Manual
Page 44: Ilom default settings, How to configure ilom using a serial connection, Before you begin
![background image](/manuals/153410/44/background.png)
3-4
Sun Fire X4100 and Sun Fire X4200 Servers System Management Guide • December 2005
3.1.2
ILOM Default Settings
Sun
™
has configured the ILOM hardware and firmware on your server to reflect the
most common default settings used in the field. It is unlikely that you will need to
change these defaults.
3.2
How To Configure ILOM Using a Serial
Connection
You can configure the ILOM SP at any time by connecting a terminal or PC running
terminal emulation software to the SP RJ-45 serial port on the GRASP board. Use
this procedure to establish a serial connection to the ILOM SP and to perform initial
configuration of ILOM firmware.
3.2.1
Before You Begin
1. Verify that your terminal, laptop, or terminal server is operational.
2. Configure that terminal device or the terminal emulation software running on a
laptop or PC to the following settings:
■
8N1: eight data bits, no parity, one stop bit
■
9600 baud
■
Disable hardware flow control (CTS/RTS)
TABLE 3-2
ILOM Default Settings
System Component
Default Status
Action Required
ILOM Service Processor card
Preinstalled
None
ILOM Service Processor
firmware
Preinstalled
None
ILOM IPMI interface
Enabled
None
ILOM web GUI
Enabled
None
ILOM command-line interface
(CLI)
Enabled
None
ILOM SNMP interface
Enabled
None