Serial interface control commands, 1 at\q flowcontrol, At\q flowcontrol – Siemens MC55 User Manual
Page 89: At\q, 0 wh, Obile
MC55 AT Command Set
4. Serial Interface Control Commands
s
m
obile
MC55_ATC_V01.05
Page 89 of 469
2/10/04
Confidential / Released
4.
Serial Interface Control Commands
The AT Commands described in this chapter allow the external application to determine various settings related
to the MC55's serial interface.
4.1
AT\Q Flowcontrol
Syntax
Parameter Description
[0]
(&F)
disable flow control
1
XON/XOFF software flow control
2
only CTS by DCE
3
RTS/CTS hardware flow control
Recommended for the following procedures: incoming or outgoing data calls,
fax calls, MUX mode.
Often, the initialization routine of Fax programs includes enabling RTS/CTS
handshake, eliminating the need to issue
3 once again.
Notes
• When using XON/XOFF flow control (
1) in online mode,
should not be used while the data trans-
mission is paused with XOFF. Before entering the command mode with
the paused transmission should
be resumed using the XON character.
• For compatibility reasons, the
command can be used in Multiplex mode, though the settings will not
take effect. However, be aware that whenever you use the
write command in Multiplex mode and then
save the current configuration to the user profile with
, the changed
setting will become active after
restart.
Exec Command
AT\Q
]
Response(s)
OK
If RTS/CTS flow control is not supported by interface and
is 2 or 3:
ERROR
PIN
ASC0
ASC1
MUX1
MUX2
MUX3
!
%
%
§
§
§
Reference(s)
V.25ter
(num)(&W)(&V)