Obile – Siemens MC55 User Manual
Page 145
MC55 AT Command Set
7.5 ATD>
s
m
obile
MC55_ATC_V01.05
Page 145 of 469
2/10/04
Confidential / Released
7.5
ATD>
memory
Syntax
Command Description
TA attempts to set up an outgoing call to the stored number. The termination character ";" is mandatory since
dialing from a phonebook is only supported for voice calls and for sending *# codes of Supplementary Services
or other functions.
Parameter Description
Integer type memory location in the range of locations available in the selected memory, i.e. the index number
returned by
String of GSM modifiers:
I Activates CLIR (disables presentation of own phone number to called party)
i Deactivates CLIR (enables presentation of own phone number to called party)
Notes
• This command may be aborted generally by receiving a character during execution. Abortion is not possible
Exec Command
ATD>
];
Response(s)
ERROR
+CME ERROR:
If no dialtone (parameter ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If connection cannot be set up:
NO CARRIER
When TA returns to command mode after call release:
OK
If successfully connected:
OK
PIN
ASC0
ASC1
MUX1
MUX2
MUX3
%
%
§
%
§
§
Reference(s)
V.25ter
(num)
(str)