MC55 AT Command Set
9.5 AT+CCUG
s
m
obile
MC55_ATC_V01.05
Page 221 of 469
2/10/04
Confidential / Released
Parameter Description
explicit CUG invocation options
0
(D)
Deactivate explicit CUG invocation
1
Activate explicit CUG invocation
0-9
explicit selection of CUG index
10
(D)
No index (preferred CUG taken from subscriber data)
state of the call
0
(D)
no information
1
suppress outgoing access
2
suppress preferential CUG
3
Suppress preferential CUG and Outgoing Access.
Notes
• The active settings for omitted parameters are retained without changes.
• Explicit CUG invocation means that at each call setup, CUG information is added to the called number.
• Upon delivery, settings are predefined with
=0,
=10,
=0.
These delivery defaults cannot be recalled automatically.
, Parameter 'G' or 'g' of command
will have no effect if the option selected
for this single call is identical to the option already selected with
.
• Current settings are saved in the ME automatically.
•
or
do not influence the current settings.
• some combinations of parameters may lead to rejection of CUG calls by the network. For more information,
please consult GSM 04.85