Table for DFSMS Library Failure Messages or Exception Conditions

Table 12. DFSMS Messages Based on Library Failure or Exception Conditions

Resulting Console Message

Action

CBR3711I Unexpected ERA code

ERA-code

from

library

library-name

.

An error has been detected during processing in tape
library

library-name

. The library returned a unit check with

error recovery action code

ERA-code

, which is an

unexpected or inappropriate response to the library
request.

It is likely that the microcode in the library and the
software are not at the correct level.

Contact your service representative.

CBR3712I Unexpected completion code, CC=

cc

, from

library

library-name

.

An error has been detected during processing in tape
library

library-name

. An unexpected or inappropriate

completion code

cc

has been received from the library.

It is likely that the microcode in the library and the
software are not at the correct level.

Contact your service representative.

CBR3721I Library

library-name

in manual mode.

Library

library-name

is in manual mode and cannot

complete or accept library audit requests. Any pending
audit requests queued within the library when it was
placed in manual mode are failed resulting in this
message. Any subsequent audit requests issued to the
library will also fail and result in this message.

When the library has returned to auto mode, resubmit the
audit requests.

CBR3722I Library

library-name

equipment check.

A library hardware failure has been detected by the
library or one of the associated tape subsystems. The
failing library component must be repaired before library
requests can be completed successfully.

Contact your service representative.

CBR3724I Volume

volser

does not exist in library

library-name

.

Volume

volser

does not reside in library

library-name

. It is

possible that the volume has been ejected from the
library by another host system.

1. Use the ISMF mountable tape volume list function to

examine the current state of the volume under
DFSMS.

2. Determine where the volume is and re-enter it into the

library’s input station.

CBR3725I Library

library-name

command reject for

volume

volser

. Library error code=

error-code

.

A request for a library operation with volume

volser

has

been rejected by library

library-name

. The error code

indicates the reason for the rejection, but is included for
diagnostic purposes only.

It is likely that the microcode in the library and the
software are not at the correct level.

Contact your system administrator.

Chapter 8. Problem Determination Procedures