Table 7. Operator Intervention Messages and Parameters (OPINT TRAP Type) (continued)

OPINT #

Parameter

[A]

Parameter

[B]

Parameter

[C]

Actual Library Manager OPINT Trap

Message

9

Volser

An unexpected volser (

[A]

) was found and

ejected to the convenience I/O station.

10

*The high-capacity output rack is full.

11

Volser

Rack Cell

A duplicate volser (

[A]

) was left in

high-capacity input rack cell

[B]

12

Rack Cell

An unreadable volser was left in

high-capacity input rack cell

[A]

13

Volser

Rack Cell

An invalid volser (

[A]

) was left in

high-capacity input rack cell B

14

Volser

An invalid volser (

[A]

) was left in the

convenience I/O station

15

Volser

Rack Cell

A duplicate volser (

[A]

) was ejected to

high-capacity output rack cell

[B]

16

Volser

Rack Cell

An unexpected volser (

[A]

) was ejected to

high-capacity output rack cell

[B]

17

Device

Load / unload failure on device

[A]

.

18

Volser

An unexpected volser (

[A]

) was left in the

convenience I/O station.

19

Volser

Rack Cell

An unexpected volser (

[A]

) was left in

high-capacity output rack cell

[B]

20

*The convenience I/O station door is open.

21

*The convenience I/O station door is open.

22

Volser

Volser (

[A]

) could not be put away. It was

ejected to the convenience I/O station.

23

Volser

Rack Cell

Volser (

[A]

) could not be put away. It was

ejected to the high-capacity output rack cell

[B]

.

24

The convenience I/O station should be

empty but is not. Visually check the station.

25

Gripper

Accessor

A cartridge could not be released from

gripper

[A]

accessor

[B]

.

26

Volser

A cartridge has been dropped. (

[A]

)

27

Environmental alert - Smoke has been

detected in the enclosure.

28

An emergency stop has occurred.

29

Volser

Damaged volser (

[A]

) ejected to the

convenience I/O station.

30

Volser

Rack Cell

Damaged volser (

[A]

) ejected to

high-capacity output facility cell:

[B]

31

Device

Device

[A]

is not ready.

34

Device

A mislabeled cleaner cartridge has been left

in device

[A]

feed slot. Remove the

cartridge.

35

Device

A recoverable error occurred on device

[A]

.

A service call may be needed if the error

persists.

Chapter 6. Advanced Operating Procedures