beautypg.com

IBM Tape Library Magstar 3494 User Manual

Page 238

background image

This indicates that the parameter is not used for this Library Manager
OPINT messages.

Gripper

Valid Gripper values are: 1, which indicates gripper one; and 2, which
indicates gripper two.

Accessor

Valid Accessor values are: A, which indicates accessor A; and B, which
indicates accessor B.

Note: Only High Availability 3494s have an accessor B.

Device

Valid Device values will be from 0 to 0xFFF. This parameter will always be
reported in hexadecimal.

Volser This will be a six character string (example: CNN444).

Rack Cell

The Rack Cell parameter has the following format: RackColumnCell. As an
example: 1G1 means rack 1, column G and cell 1.

External

Same as Volser - Only used in libraries with VTSs.

Internal

Same as Volser - Only used in libraries with VTSs.

VTS

Valid VTS parameters are:

v

VTS_1, which indicates VTS 1

v

VTS_2, which indicates VTS 2

Certain versions of OS/2 trap if the overall SNMP message is over 132 bytes in
length. To prevent this trap, the Library Manager software checks to see if the
SNMP trap message is longer than 132 bytes, and inserts a NULL character at the
132 byte limit. Therefore, some Library Manager OPINT SNMP traps will be
truncated to prevent this problem.

Table 7 contains the Library Manager OPINT interventions.

Table 7. Operator Intervention Messages and Parameters (OPINT TRAP Type)

OPINT #

Parameter

[A]

Parameter

[B]

Parameter

[C]

Actual Library Manager OPINT Trap

Message

1

Gripper

Accessor

Gripper Failure on gripper

[A]

, accessor

[B]

2

Device

Index failure on device

[A]

3

*The convenience I/O station is full.

4

*The library is full.

5

Volser

A duplicate volser (

[A]

) was ejected to the

convenience I/O station.

6

Volser

A duplicate volser (

[A]

) was left in the

convenience I/O station

7

An unreadable volser was left in the

convenience I/O station

8

*The library is out of CST/ECCST cleaner

cartridges.

216