beautypg.com

Mib-ii system group (mib-ii syst), Cam configuration group (cam), Table 6.6 – Motorola CAJUN P120 User Manual

Page 67: Cam group parameters

background image

Chapter 6

Legacy CLI (Command Line Interface)

Cajun P120 User’s Guide

53

MIB-II System Group (MIB-II SYST)

This group provides the MIB-II configuration according to the IETF standard
MIB-II, System Group.

To view or change these parameters, type the command:

set|show mibII-syst list

The output is as follows:

mibII-syst>contact-system [UNKNOWN ]

mibII-syst>name-system [CajunP120 ]

mibII-syst>location-system [UNKNOWN ]

CAM Configuration Group (CAM)

This group includes parameters for the configuration of the CAM software. The
table below displays the parameters, a description of the parameters, the default
values, and the valid range of values.

The syntax for this command is:

set|show cam list

Table 6.6

CAM Group Parameters

Parameter

Description

Default
Value(s)

Valid Range
for Values

AGINGMODE

Enables aging

dis

ena, dis

AGETIMEOUT

Time interval for
CAM aging

63

1-63

AGINGMODE

Determines whether or not aging is enabled on the CAM.
When enabled, the MAC addresses that have not been used
recently are deleted. The CAMENA parameter must also be set
to enable for the aging function to work.

AGETIMEOUT

The time interval for CAM aging. One (1) is the minimum
timeout and 63 is the maximum. Each timeout unit is about 8
seconds.