beautypg.com

A. specifications, Cajun p120 switch, Physical – Motorola CAJUN P120 User Manual

Page 115: Power requirements, Environmental, Safety, Appendix a, Specifications cajun p120 switch, Physical power requirements environmental safety, Specifications

background image

Cajun P120 User’s Guide

101

Appendix A

Specifications

Cajun P120 Switch

Physical

Power Requirements

Environmental

Safety

UL for US approved according to UL195O Std.

C-UL(UL for Canada) approved according to C22.2 No.950 Std.

CE for Europe approved according to EN 60950 Std.

Overcurrent Protection: A readily accessible Listed safety-approved protective
device with a 16A rating must be incorporated in series with building
installation AC power wiring for the equipment under protection.

Height

2U (88 mm, 3.5”)

Width

482.6 mm (19”)

Depth

450 mm (17.7”)

Weight

7.3 kg (16.1 lbs)

Input voltage

100 to 240 VAC, 50/60 Hz

BTU

The worst case for BTU for the Cajun P120 with an
Expansion sub-module is ~273 BTU

Power dissipation

80 W

Operating Temp.

0-40°C (32-105°F)

Rel. Humidity

5% to 95% non-condensing