Front or rear identify/fault led blinks amber, 2 front or rear identify/fault led blinks amber, 146 operating manual – FUJITSU PRIMERGY BX600 S3 User Manual

Page 146: Troubleshooting and tips

background image

146

Operating Manual

BX600

S3

Troubleshooting and Tips

©

c

ogn

it

a

s

.

G

e

s

e

lls

c

h

ft

f

ü

r T

e

c

h

ni

k

-D

o

k

u

m

e

n

ta

ti

on m

b

H

20

09

P

fad

:

H

:\

A

p

ri

l\

P

R

IM

E

R

GY

_R

eb

rand

in

g

\v

o

n W

a

lt

er

\b

x

600

_s

3_

ba\

B

X

6

0

0

S

3

_

e

n

\b

la

d

e

-u

s.

k1

4

14.2

Front or Rear Identify/Fault LED Blinks
Amber

If the front or rear identify/fault indicator blinks amber (see

section “Operating

and Indicator Elements of the Basic Unit” on page 50

) one of the malfunctions

described below may have occurred in the system:

One of the power supply units fails

The PSU status LED is unlit and/or the PSU fan failure LED blinks green if there
is an error in the corresponding power supply unit, e.g. (see also

figure “Power

supply unit: LEDs” on page 132

):

General failure (alert or fan #1 shutdown)

Overtemperature (any of the fans are not working properly in the correspon-
ding unit)

Overcurrent

Over- or undervoltage

The PSU is reaching the end of its life or is operating in an environment
which exceeds the specified limits.

Ê

Check the PSU status and/or fan failure LEDs to identify the defective unit
and exchange it (see

section “Replacing a Power Supply Unit” on page 133

).

One of the fans in the rear fan modules has failed

Even though the system can continue operating without one of the fans in the
rear fan modules, you should:

Ê

Exchange the defective front fan module within a reasonable amount of time
(see

section “Replacing the Fan Unit” on page 141

and

section “Replacing

a Fan in the Unit” on page 143

).

Switch blade fails

The failure LED of the switch blade lights up if there is a general error there.

Ê

Check the switch blade failure LEDs to identify the defective unit.

Ê

If the switch blade is still indicated as defective, exchange it (see

section

“Installing an I/O Blade” on page 96

).