beautypg.com

Chart 4-3. hpf flowsensor troubleshooting, Iv -20 – Hale 5.0 FoamLogix User Manual

Page 114

background image

IV

-20

ROTARY GEAR PUMP

ELECTRONIC FOAM PROPORTIONING SYSTEM

Section

IV

: Operation

Chart 4-3. HPF Flowsensor Troubleshooting

START

IS WATER

FLOWING?

IS CONTROL UNIT

DISPLAY LIGHTED?

IS FLOW LED ON

CONTROL UNIT

LIGHTED?

DOES WATER FLOW

RATE SHOW ON

CONTROL UNIT?

DOES WATER FLOW

RATE SHOW

ACCURATELY ON

CONTROL UNIT?

ESTABLISH WATER FLOW

IN ACCORDANCE WITH

APPARATUS OPERATING

PROCEDURES

PROCEED TO

POWER SUPPLY

TROUBLESHOOTING

CHART 4-2

PRESS SELECT

DISPLAY BUTTON

UNTIL FLOW LED

LIGHTS

SHUTDOWN WATER

FLOW AND REMOVE

FLOWSENSOR

FROM TEE

SEE USER

CALIBRATION

PROCEDURES IN

SECTION III AND

CALIBRATE

FLOWSENSOR?

CONTINUE SYSTEM

TROUBLESHOOTING

USING CHART 4-1

IS FLOWSENSOR

PADDLEWHEEL

JAMMED?

CAN

PADDLEWHEEL

BE FREED?

REPLACE

FLOWSENSOR

SPIN

PADDLEWHEEL

BY HAND

DOES WATER

FLOW RATE

SHOW ON

CONTROL UNIT?

DISCONNECT FLOWSENSOR

CABLE AND CONNECT A NEW

CABLE TO CONTROL UNIT.

SPIN PADDLEWHEEL

DOES WATER FLOW

RATE SHOW ON

CONTROL UNIT?

REPLACE

FLOWSENSOR

SECURE NEW

FLOWSENSOR

CORDSET

NO

YES

NO

YES

NO

YES

NO

YES

NO

YES

YES

NO

YES

NO

NO

YES

NO

YES

This manual is related to the following products: