beautypg.com

Tlt,par: setting the tiltmeter, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 498: Relevant query command

background image

484

Set Command Library

TLT,PAR: Setting the Tiltmeter

Function

This command is used to define all the parameters needed to
communicate with the tiltmeter.

Following the execution of this command, and then that of
$PASHS,OUT,x,TLT,ON, the receiver will regularly query the
tiltmeter by sending the trigger string every x seconds of
query interval.

Command Format

Syntax

$PASHS,TLT,PAR,c1,s2,s3,d4[*cc]

Parameters

Comments

• This command overwrites all the settings previously

performed with the following commands:

– $PASHS,TLT,INIT

$PASHS,TLT,INTVL

– $PASHS,TLT,CMD

• In fact, the $PASHS,TLT,PAR command is used for the

same purpose as, and is more convenient than, the above
three commands, which are maintained only for the sake
of compatibility with the Ashtech iCGRS reference station.

Example

Setting the tiltmeter connected to port F:

$PASHS,TLT,PAR,F,*9900ID,*0100XY,10*1C

Relevant Query

Command

$PASHQ,TLT

Parameter

Description

Range

Default

c1

Receiver serial port connected to
the tiltmeter.

A, B, F

s2

Initialization string

20 characters max.

s3

Trigger string

20 characters max. 0100XY

d4

Query interval, in seconds. “0”
means no query.

0; 1-68400

1

*cc

Optional checksum

*00-*FF