Tlt,par: setting the tiltmeter, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 498: Relevant query command
484
Set Command Library
TLT,PAR: Setting the Tiltmeter
Function
This command is used to define all the parameters needed to
communicate with the tiltmeter.
Following the execution of this command, and then that of
$PASHS,OUT,x,TLT,ON, the receiver will regularly query the
tiltmeter by sending the trigger string every x seconds of
query interval.
Command Format
Syntax
$PASHS,TLT,PAR,c1,s2,s3,d4[*cc]
Parameters
Comments
• This command overwrites all the settings previously
performed with the following commands:
– $PASHS,TLT,INIT
–
$PASHS,TLT,INTVL
– $PASHS,TLT,CMD
• In fact, the $PASHS,TLT,PAR command is used for the
same purpose as, and is more convenient than, the above
three commands, which are maintained only for the sake
of compatibility with the Ashtech iCGRS reference station.
Example
Setting the tiltmeter connected to port F:
$PASHS,TLT,PAR,F,*9900ID,*0100XY,10*1C
Relevant Query
Command
$PASHQ,TLT
Parameter
Description
Range
Default
c1
Receiver serial port connected to
the tiltmeter.
A, B, F
s2
Initialization string
20 characters max.
s3
Trigger string
20 characters max. 0100XY
d4
Query interval, in seconds. “0”
means no query.
0; 1-68400
1
*cc
Optional checksum
*00-*FF