Spectra Precision ProFlex 800 Reference Manual User Manual
Page 208
194
Web Server Help Files Collection
Caster Information
All the data you provide in this section are for insertion in the
source table. Being only informative and optional, they do not
affect the way the NTRIP Caster works.
Show Characters
Use this option to show or hide the
above password. When hidden, the
password is replaced with bullet char-
acters.
-
Maximum Simultaneous
Connections Per User
Use this field to limit the number of
connections an identified user is
allowed to establish at any given time.
CST,PAR
Parameter
Designation
$PASHS
Caster Identifier
Enter the caster identifier, e.g. the name of
the provider.
CST,PAR
Caster Operator
Enter the name of the institution, agency or
company operating the caster
CST,PAR
Latitude,
Longitude
Enter the approximate position of the NTRIP
caster.
• Latitude, in degrees, two digits after deci-
mal point (0 to ±90.00)
• Longitude, in degrees, two digits after
decimal point (0 to 360.00)
CST,PAR
Fallback Caster IP
Address,
Fallback Caster
Port Number
The source table may provide users with
information allowing them to connect to
another IP address and port in case the
NTRIP caster is no longer accessible.
CST,PAR
Network Identifier
Enter the network identifier, e.g. the name of
the network of GNSS permanent reference
stations.
CST,PAR
Network Operator
Enter the name of the institution, agency or
company operating the network.
CST,PAR
Country
Enter the three-letter standard abbreviation
of the country (country code; see ISO 3166)
where the NTRIP caster is operated.
CST,PAR
Fee
Indicate whether users are charged for using
the corrections available through the NTRIP
Caster. This is just a reminder for the admin-
istrator. Enabling or disabling this button has
no impact on the way the caster works.
CST,PAR
Web Address for
Network Informa-
tion
Enter the address of the web site where
users can get additional information about
the NTRIP caster network.
CST,PAR
Parameter
Designation
$PASHS