141
Web Server Help Files Collection
through the Internet (port Q). See the description of each
parameter in the table below.
Setting a Base to
Generate Data Streams
on its Ethernet Port
This page is an abridged version of the Base Setup-Full Setup
page only showing the settings required to configure a base
for generating data streams on its Ethernet port (ports I1 to
I9).
Parameter
Designation
$PASHS
Connection
Choose the type of network connection used in the
receiver to connect to the NTRIP caster:
• None: No connection to an NTRIP caster required
• External NTRIP Caster via Ethernet: The base is
directly connected to the Internet through its Ether-
net port (port Q used).
• Embedded NTRIP Caster: (Available only if the
NTRIP caster option is installed): The base delivers
its data to the embedded NTRIP caster.
MDM,..
NTR,PAR
Connect
Now
Check this button to let the receiver perform the
requested network connection after you have clicked
on the Configure button.
Address,
Port, Mount
Point, Pass-
word
Enter the network information relevant to the NTRIP
caster to which the base is expected to deliver its
data.
When the base delivers its data to the embedded
NTRIP caster, there is no password or IP address
needed. You only have to choose the mount point
through which the data from the base will be made
available to users through the NTRIP caster.
Message
Choose the type of message generated by the base.
Then place the mouse cursor over the ”I” sign (to the
right of the Message drop-down list) to read the
details of the currently set messages.
-