Meteorological unit – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 184
170
Web Server Help Files Collection
Meteorological
Unit
The Meteorological Unit page is used to set the conditions in
which the receiver will communicate with and get information
from the meteorological unit.
For each serial port (A, B, F), the following parameters can be
set to allow a connection to the meteorological unit:
“Update Now” but-
ton
Use this button to force the receiver to send
its IP address right away to the DynDNS
server.
DDN,SET
Parameter
Designation
$PASHS
Parameter
Designation
$PASHS
Process meteorological
unit
Enable this option to allow the
receiver to query the meteorological
unit, if connected to this port.
MET
Baud Rate
Set the port baud rate
PRT
Mode
Set the port mode (RS232 or RS422).
Only port A can be RS422 or RS232.
All the others are necessarily RS232.
MDP
RTS/CTS
Enable or disable the handshaking
protocol on this port.
CTS
Initialization string
Define the string used by the receiver
to initialize the meteorological unit, if
connected to this port.
MET
Trigger string
Define the string used by the receiver
to query the meteorological unit, if
connected to this port.
MET