Serial ports, Bluetooth/modem connections – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 176

162
Web Server Help Files Collection
Serial Ports
This page is used to set the receiver serial ports (A, B and F).
For each port, set the parameters below.
Bluetooth/Modem
Connections
This page is used to define the properties of the receiver’s
Bluetooth and internal modem devices. The following groups
of parameters need to be defined:
• Bluetooth
Maximum Base-
line Elevation
Set the maximum value of expected base-
line elevation (0-90°; Default: 15°).
CPD,ARR,PAR
Elevation Offset
Designates the angle deviation (±90°)
between the orientation of the baseline and
the orientation of the object for which you
want to determine the roll or pitch angle.
This parameter makes sense in a ship for
example where the baseline resulting from
the installation of the two antennas is not
parallel to the orientation of the deck
(default: 0).
Keep this parameter equal to zero if it does
not make sense to define an elevation off-
set in your application.
CPD,ARR,OFS
Maximum Base-
line Length Error
Set the maximum error that is tolerated in
the determination of the baseline length
(0.001-10.000 meters)
CPD,ARR,PAR
Parameter
Designation
$PASHS
Parameter
Designation
$PASHS
Baud Rate
Choose an option from the drop-down list.
PRT
Mode
(Port A only) Choose an option from the drop-down
list (RS232 or RS 422).
MDP
RTS/CTS
Enable or disable the handshaking protocol.
CTS
Power ON
(Ports B & F only) Use this option to turn on or off
ports B and F.
ECP,ON
or OFF