339

Set Command Library

CMR,TYP: CMR Message Type and Rate

Function

This command is used in a base to set the type and rate of
CMR message the base will generate and output.

Command Format

Syntax

$PASHS,CMR,TYP,d1,d2[*cc]

Parameters

Examples

Setting a CMR message type 0 (observables) at a 1-second
output rate:

$PASHS,CMR,TYP,0,1*59

Setting a CMR message type 1 (base coordinates) at a 30-
second output rate:

$PASHS,CMR,TYP,1,30*6A

Relevant Query

Command

$PASHQ,CMR,MSI

See also

$PASHS,BAS

$PASHS,CPD,MOD,BAS

$PASHS,BDS

Parameter

Description

Range

d1

Message type

0, 1, 2, 3 (See table below)

d2

Output rate in seconds

0, 0.5 or 1-300 (See table below)

*cc

Optional checksum

*00-*FF

Message

Type

Description

Output Rate (Range)

Output Rate

(Default)

0

Observables

0, 0.5 s or 1-300 s

1 s

1

Base coordinates

0-300 s

30 s

2

Base description

0-300 s

30 s

3

GLONASS observables

0, 0.5 s or 1-300 s

1 s