Bds: setting differential data streams on ports ix, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 341
327
Set Command Library
$PASHS,RNX,TYP
$PASHS,CMR,TYP
BDS: Setting Differential Data Streams on Ports Ix
Function
This command allows you to define differential data
messages you wish to make available on ports I1 to I9 for data
streaming through TCP/IP connections.
Command Format
Syntax
$PASHS,BDS,s1,s2,s3[*cc]
Parameters
The default settings are given in the table below.
Examples
Enabling RTCM 3 differential data on port I3:
$PASHS,BDS,RT3,I3,ON*42
Disabling RTCM 2.3 differential data on port I1:
Parameter
Description
Range
s1
Differential data type:
• RT2: RTCM 2.3 messages
• RT3: RTCM 3.0&3.1 messages
• CMR: CMR messages
• CMP: CMR+ messages
• ATM: ATOM messages
• DBN: DBEN messages
RT2, RT3, CMR,
CMP, ATM, DBN
s2
Data stream port
I1-I9
s3
Enable/disable control parameter
ON, OFF
*cc
Optional checksum
*00-*FF
RT2
RT3
CMR
CMP
ATM
I1
OFF
ON
OFF
OFF
OFF
I2
OFF
OFF
OFF
OFF
OFF
I3
OFF
OFF
OFF
OFF
OFF
I4
OFF
OFF
OFF
OFF
OFF
I5
OFF
OFF
OFF
OFF
OFF
I6
OFF
OFF
OFF
OFF
OFF
I7
OFF
OFF
OFF
OFF
OFF
I8
OFF
OFF
OFF
OFF
OFF
I9
OFF
OFF
OFF
OFF
OFF