Emerson Process Management MICRO MOTION 2400S User Manual
Page 159

Configuration and Use Manual
151
Device Profile
D
e
vice Pr
ofile
In
de
x
Displa
y Codes
Men
u
s
14
Alarm status 3
UINT
Get
V
A collection of status bits
• 0x0001 = Not used
• 0x0002 = Power reset
• 0x0004 = Transmitter
initializing
• 0x0008 =
Transmitter/sensor
communications fault
(A28)
• 0x0010 = Not used
• 0x0020 = Not used
• 0x0040 = Not used
• 0x0080 =
Transmitter/sensor
communications fault
(A26)
• 0x0100 = Calibration
failed
• 0x0200 = Calibration
failed: Low
• 0x0400 = Calibration
failed: High
• 0x0800 = Calibration
failed: Noisy
• 0x1000 = Transmitter
failed
• 0x2000 = Data loss
• 0x4000 = Calibration
in progress
• 0x8000 = Slug flow
Table C-7
Diagnostics Object (0x66) – Instance 1 continued
Attrib
ID
Name
Data type
Service
Mem
Description
Comments