Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual
Page 316

9 Appendix
9.1.2 Parameters
9-18
Pn50E
2
Output Signal Selection 1
0000 to 3333
−
0000
After restart
Setup
−
−
Pn50F
2
Output Signal Selection 2
0000 to 3333
−
0100
After restart
Setup
−
−
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Profile
Reference
Section
Positioning Completion Signal Mapping (/COIN)
Reference
Section
0
Disabled (the above signal is not used.)
4.8.6
1
Outputs the signal from CN1-1, 2 output terminal.
2
Outputs the signal from CN1-23, 24 output terminal.
3
Outputs the signal from CN1-25, 26 output terminal.
Speed Coincidence Detection Signal Mapping (/V-CMP)
Reference
Section
0 to 3
Same as /COIN Signal Mapping.
4.8.5
Servomotor Movement Detection Signal Mapping (/TGON)
Reference
Section
0 to 3
Same as /COIN Signal Mapping.
4.8.3
Servo Ready Signal Mapping (/S-RDY)
Reference
Section
0 to 3
Same as /COIN Signal Mapping.
4.8.4
4th 3rd 2nd 1st
digit digit digit digit
n.
Force Limit Detection Signal Mapping (/CLT)
Reference
Section
0
Disabled (the above signal is not used.)
4.6.3
1
Outputs the signal from CN1-1, 2 output terminal.
2
Outputs the signal from CN1-23, 24 output terminal.
3
Outputs the signal from CN1-25, 26 output terminal.
Speed Limit Detection Signal Mapping (/VLT)
Reference
Section
0 to 3
Same as /CLT Signal Mapping.
4.8.8
Brake Signal Mapping (/BK)
Reference
Section
0 to 3
Same as /CLT Signal Mapping.
4.3.4
Warning Signal Mapping (/WARN)
Reference
Section
0 to 3
Same as /CLT Signal Mapping.
4.8.2
4th 3rd 2nd 1st
digit digit digit digit
n.