Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual
Page 289

8 Troubleshooting
8.2.2 Troubleshooting of Warnings
8-28
A.95A
Command 
Warning 1
(Unsatisfying 
Command)
Command sending con-
dition is not satisfied.
Refer to 8.3 Monitoring Communica-
tion Data on Occurrence of an Alarm 
or Warning to determine which 
command was the cause of the 
warning.
Send a command after command
sending condition is satisfied.
A.95B
Command 
Warning 2
(Non-supported 
Command)
SERVOPACK received
unsupported command.
Refer to 8.3 Monitoring Communica-
tion Data on Occurrence of an Alarm 
or Warning to determine which 
command was the cause of the 
warning.
Do not sent an unsupported command.
A.95D
Command 
Warning 4
(Command Inter-
ference)
Command sending con-
dition for latch-related 
commands is not satis-
fied.
Refer to 8.3 Monitoring Communica-
tion Data on Occurrence of an Alarm 
or Warning to determine which 
command was the cause of the 
warning.
Send a command after command 
sending condition is satisfied.
A.95E
Command 
Warning 5
(Subcommand 
Disable)
Subcommand sending 
condition is not satis-
fied.
Refer to 8.3 Monitoring Communica-
tion Data on Occurrence of an Alarm 
or Warning to determine which 
command was the cause of the 
warning.
Send a command after command 
sending condition is satisfied.
A.95F
Command Warn-
ing 6
(Undefined Com-
mand)
Undefined command 
was sent.
Refer to 8.3 Monitoring Communica-
tion Data on Occurrence of an Alarm 
or Warning to determine which 
command was the cause of the 
warning.
Do not use an undefined command.
A.960
MECHATROLINK
Communications
Warning
MECHATROLINK 
wiring is incorrect.
Confirm the wiring.
Correct the MECHATROLINK wir-
ing.
Or, connect a terminal to the terminal 
station.
MECHATROLINK 
data reception error 
occurred due to noise 
interference.
Confirm the installation conditions.
Take measures against noise. Check 
the MECHATROLINK communica-
tions cable and FG wiring and take 
measures such as adding ferrite core 
on the MECHATROLINK communi-
cations cable.
A SERVOPACK fault 
occurred.
–
A fault occurred in the SERVOPACK.
Replace the SERVOPACK.
A.962
MECHATROLINK
Communications
Warning
(FCS Error)
MECHATROLINK 
wiring is incorrect.
Confirm the wiring.
Correct the MECHATROLINK wir-
ing.
Or, connect a terminal to the terminal 
station.
MECHATROLINK 
data reception error 
occurred due to noise 
interference.
Confirm the installation conditions.
Take measures against noise. Check 
the MECHATROLINK communica-
tions cable and FG wiring and take 
measures such as adding ferrite core 
on the MECHATROLINK communi-
cations cable.
A SERVOPACK fault 
occurred.
–
A fault occurred in the SERVOPACK.
Replace the SERVOPACK.
(cont’d)
Warning Num-
ber: Warning
Name (Warning
Description)
Cause
Investigative Actions
Corrective Actions