2 warning displays, 1 list of warnings – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual
Page 285

8 Troubleshooting
8.2.1 List of Warnings
8-24
8.2 Warning Displays
The following sections describe troubleshooting in response to warning displays.
The warning name and warning meaning output are listed in order of the warning numbers in 8.2.1 List of
Warnings.
The causes of warnings and troubleshooting methods are provided in 8.2.2 Troubleshooting of Warnings.
8.2.1 List of Warnings
This section provides list of warnings.
Warning
Number
Warning Name
Meaning
Reset
A.900
*1
Position Error Overflow
Position error exceeded the parameter setting
(Pn520
×Pn51E/100).
Required
A.901
*1
Position Error Overflow
Alarm at Servo ON
When the servomotor power is ON, the position error exceeded
the parameter setting (Pn526
×Pn528/100).
Required
A.910
*1
Overload
This warning occurs before the overload alarms (A.710 or
A.720) occur. If the warning is ignored and operation contin-
ues, an overload alarm may occur.
Required
A.911
*1
Vibration
Abnormal vibration at the motor speed was detected. The
detection level is the same as A.520. Set whether to output an
alarm or warning by the vibration detection switch (Pn310).
Required
A.920
*1
Regenerative Overload
This warning occurs before the regenerative overload alarm
(A.320) occurs. If the warning is ignored and operation contin-
ues, a regenerative overload alarm may occur.
Required
A.921
*1
Dynamic Brake Overload
This warning occurs before dynamic brake overload alarm
(A.731) occurs. If the warning is ignored and operation contin-
ues, a dynamic brake overload alarm may occur.
Required
A.94A
*2
Data Setting Warning 1
(Parameter Number Error) Incorrect command parameter number was set.
Automatic
reset
*4
A.94B
*2
Data Setting Warning 2
(Out of Range)
Command input data is out of range.
Automatic
reset
*4
A.94C
*2
Data Setting Warning 3
(Calculation Error)
Calculation error was detected.
Automatic
reset
*4
A.94D
*2
Data Setting Warning 4
(Parameter Size)
Data size does not match.
Automatic
reset
*4
A.94E
*2
Data Setting Warning 5
(Latch Mode Error)
Latch mode error is detected.
Required
A.95A
*2
Command Warning 1
(Unsatisfying Command)
Command was sent although the conditions for sending a com-
mand were not satisfied.
Automatic
reset
*4
A.95B
*2
Command Warning 2
(Non-supported Com-
mand)
Unsupported command was sent.
Automatic
reset
*4
A.95D
*2
Command Warning 4
(Command Interference)
Command, especially latch command, interferes.
Automatic
reset
*4
A.95E
*2
Command Warning 5
(Subcommand Disable)
Subcommand and main command interfere.
Automatic
reset
*4
A.95F
*2
Command Warning 6
(Undefined Command)
Undefined command was sent.
Automatic
reset
*4
A.960
*2
MECHATROLINK
Communications Warning
Communications error occurred during MECHATROLINK
communications.
Required
A.962
*2
MECHATROLINK
Communications Warning
(FCS Error)
Communications error occurred during MECHATROLINK
communications.